Comment about: "Feasibility of closed-loop titration of propofol and remifentanil guided by the bispectral monitor in pediatric and adolescent patients: a prospective randomized study"

  • César Augusto Candia-Arana Service of Anesthesia and Resuscitation, Complejo Hospitalario Universitario de Cartagena, Murcia, Spain
  • Caridad Greta Castillo-Monzón Service of Anesthesia and Resuscitation, Complejo Hospitalario Universitario de Cartagena, Murcia, Spain

References

1. Kraegen EW, Whiteside R, Bell D, Chia YO, Lazarus L. Development of a closed-loop artificial pancreas. Horm Metab Res Suppl. 1979;8:38-42.
2. Rassweiler J, Binder J, Frede T. Robotic and telesurgery: will they change our future? Curr Opin Urol. 2001;11:309-20.
3. Turchetti G, Palla I, Pierotti F, Cuschieri A. Economic evaluation of da Vinci-assisted robotic surgery: a systematic review. Surg Endosc. 2012;26:598-606.
4. O'Callaghan AC, Hawes DW, Ross JA, White DC, Wloch RT. Uptake of isoflurane during clinical anaesthesia. Servo-control of liquid anaesthetic injection into a closed-circuit breathing system. Br J Anaesth. 1983;55:1061-1.
5. Schwilden H, Stoeckel H, Schüttler J. Closed-loop feedback control of propofol anaesthesia by Quantitative EEG analysis in humans. Br J Anaesth. 1989;62:290-6.
6. Mendonca T, Magalhães H, Lago P, Esteves S. Hipocrates: a robust system for the control of neuromuscular blockade. J Clin Monit Comput. 2004;18:265-73.
7. Hemmerling TM, Taddei R, Wehbe M, Cyr S, Zaouter C, Morse J. First robotic ultrasound-guided nerve blocks in humans using the Magellan system. Anesth Analg. 2013;116:491-4.
8. Orliaguet GA, Lambert FB, Chazot T, Glasman P, Fischler M, Liu N. Feasibility of closed-loop titration of propofol and remifentanil guided by the bispectral monitor in pediatric and adolescent patients: a prospective randomized study. Anesthesiology. 2015;122:759-67.
9. Lan JY, Abbod MF, Yeh RG, Fan SZ, Shieh JS. Review: intelligent modeling and control in anesthesia. J Med Biol Eng. 2012;32:293-307.
10. Liu N, Chazot T, Hamada S, Landais A, Boichut N, Dussaussoy C, et al. Closed-loop co administration of propofol and remifentanil guided by bispectral index: a randomized multicenter study. Anesth Analg. 2011;112:46-57.
11. Liu N, Lory C, Assenzo V, Cocard V, Chazot T, Le Guen M, et al. Feasibility of closed-loop co-administration of propofol and remifentanil guided by the bispectral index in obese patients: a prospective cohort comparison. Br J Anaesth. 2015;114:605-14.
12. Dussaussoy C, Peres M, Jaoul V, Liu N, Chazot T, Picquet J, et al. Automated titration of propofol and remifentanil decreases the anesthesiologist's workload during vascular or thoracic surgery: a randomized prospective study. J Clin Monit Comput. 2014;28:35-40.
13. Le Guen M, Liu N, Tounou F, Augé M, Tuil O, Chazot T, et al. Dexmedetomidine reduces propofol and remifentanyl requirements during bispectral index-guided closed-loop anesthesia: a double-blind, placebo-controlled trial. Anesth Analg. 2014;118:946-55.
14. Liu N, Le Guen M, Boichut N, Genty A, Hérail T, Schmartz D, et al. Nitrous oxide does not produce a clinically important sparing effect during closed-loop delivered propofol-remifentanil anaesthesia guided by the bispectral index: a randomized multicentre study. Br J Anaesth. 2014;112:842-51.
15. Le Guen M, Grassin-Delyle S, Cornet C, Genty A, Chazot T, Dardelle D, et al. Comparison of the potency of different propofol formulations: a randomized, double-blind trial using closed-loop administration. Anesthesiology. 2014;120:355-64.
16. Wehbe M, Giacalone M, Hemmerling TM. Robotics and regional anesthesia. Curr Opin Anaesthesiol. 2014;27:544-8.
17. Cannesson M, Rinehart J. Closed-loop systems and automation in the era of patients' safety and perioperative medicine. J Clin Monit Comput. 2014;28:1-3.
18. Pambianco DJ, Whitten CJ, Moerman A, Struys MM, Martin JF. An assessment of computer assisted personalized sedation: a sedation delivery system to administer propofol for gastrointestinal endoscopy. Gastrointest Endosc. 2008;68:542-7.
19. Ingrande J, Lemmens HJ. Medical devices for the anesthetist: current perspectives. Med Dev (Auckl). 2014;7:45-53.
How to Cite
1.
Candia-Arana CA, Castillo-Monzón CG. Comment about: "Feasibility of closed-loop titration of propofol and remifentanil guided by the bispectral monitor in pediatric and adolescent patients: a prospective randomized study". Colomb. J. Anesthesiol. [Internet]. 2015 Jul. 1 [cited 2024 Apr. 20];43(3):234-6. Available from: https://www.revcolanest.com.co/index.php/rca/article/view/177

Downloads

Download data is not yet available.
Published
2015-07-01
How to Cite
1.
Candia-Arana CA, Castillo-Monzón CG. Comment about: "Feasibility of closed-loop titration of propofol and remifentanil guided by the bispectral monitor in pediatric and adolescent patients: a prospective randomized study". Colomb. J. Anesthesiol. [Internet]. 2015 Jul. 1 [cited 2024 Apr. 20];43(3):234-6. Available from: https://www.revcolanest.com.co/index.php/rca/article/view/177
Section
Brief academy

Altmetric

Article metrics
Abstract views
Galley vies
PDF Views
HTML views
Other views
QR Code